Grain-systems PNEG-501 Manuale Utente

Navigare online o scaricare Manuale Utente per Condizionatori Grain-systems PNEG-501. Grain Systems PNEG-501 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Application

Fan And HeaterApplicationGuidePNEG-501

Pagina 2

10Fan/Heater ApplicationEXAMPLES SITUATION:On farm aeration of dry soybeans. 42" diameter, 9 rings, NSL series farm binwith 24" eave heig

Pagina 3 - TABLE OF CONTENTS

11Fan/Heater ApplicationSITUATION SITUATION:On farm in-bin drying of corn, 24' diameter, 6 ring, FCDL series farm bin with22' eave height.

Pagina 4 - Power Warning

12Fan/Heater ApplicationINLINE CENTRIFUGAL FANSSTATIC PRESSURE IN INCHESMODEL NOH.PFAN DIA0.0 1.0 2.03.04.0 5.0 6.0 7.0 8.0 9.010.0 11.0ILC-1.51.518&q

Pagina 5 - SAFETY ALERT DECALS

13Fan/Heater ApplicationSUGGESTED AIRFLOW RATESAerationThis ventilation of stored grain to maintainuniform moisture and temperature, uses lowairflow r

Pagina 6 - FAN APPLICATION GUIDE

14Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR BEANS (W/STIRRING)321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.550.530.520.510.5140.74

Pagina 7

15Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR CORN (W/STIRRING)321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.560.540.520.510.510.5140

Pagina 8 - FAN & ROOF VENT SELECTION

16Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR RICE (W/ STIRRING)321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.640.590.540.530.520.510

Pagina 9 - AERATION SYSTEM REQUIREMENTS

17Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR WHEAT (W/ STIRRING)321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.730.650.570.550.530.52

Pagina 10 - EXAMPLES

18Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR BARLEY321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.670.610.550.540.520.520.510.510.514

Pagina 11 - SITUATION

19Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR BEANS321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.570.540.520.510.510.5140.820.690.590

Pagina 13 - SUGGESTED AIRFLOW RATES

20Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR CLOVER321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2021.501.160.830.740.660.610.580.560.550

Pagina 14 - PRESSURE CHART

21Fan/Heater ApplicationPRESSURE CHARTSTATIC CHART FOR WHITE POPCORN321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.690.620.560.540.530.520.510.510.510.5

Pagina 15

22Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR EARCORN321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.510.5140.570.530.510.5160.690.600.

Pagina 16

23Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR FLAX321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2021.501.160.830.740.660.610.580.560.550.5

Pagina 17

24Fan/Heater ApplicationPRESSURE CHARTStatic Pressure Chart For MiloGrain depth Static Pressure (inches of water column) Airflow Rate (cfm per bushel)

Pagina 18

25Fan/Heater ApplicationPRESSURE CHARTStatic Pressure Chart For OatsGrain depth Static Pressure (inches of water column) Airflow Rate (cfm per bushel)

Pagina 19

26Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR PEANUT321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.5140.530.520.5160.600.550.520.510.5

Pagina 20

27Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR POPCORN321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.610.570.530.520.520.510.510.5141.0

Pagina 21

28Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR RAPE321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2021.090.890.690.640.590.560.550.540.530.5

Pagina 22

29Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR RICE321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.680.620.560.540.530.520.510.510.510.5

Pagina 23

3Fan/Heater ApplicationTABLE OF CONTENTSRoof Warning, Operation & Safety...

Pagina 24

30Fan/Heater ApplicationPRESSURE CHARTSTATIC PRESSURE CHART FOR WHEAT321 3/4 1/2 1/3 1/4 1/5 1/7 1/10 1/15 1/2020.800.690.590.570.550.530.520.520.510.

Pagina 25

31Fan/Heater ApplicationHEATER APPLICATION & SIZINGFan selection and examination of a customer'sdrying requirements should precede heater se-

Pagina 26

32Fan/Heater ApplicationPLENUM TEMPERATURESIMPORTANT! DO NOT EXCEEDPLENUMTEMPERATURESLISTED IN TABLETHIS TABLE IS NOT INTENDED AS A DRYING GUIDE. IT S

Pagina 27

1004 E. Illinois St.Assumption, IL 62510Phone 217-226-4421Fax 217-226-4498June 1998

Pagina 28

4Fan/Heater Application Fuel WarningImportant! Do not use propane tanks which have previously been used for ammonia unless theyhave been purge

Pagina 29

5Fan/Heater ApplicationSAFETY ALERT DECALSThe GSI Group, Inc. recom-mends contacting your local powercompany, and having a representa-tive survey your

Pagina 30

6Fan/Heater Application3500RPM Vane Axial fans are normally high performance low static pressurefans. They are normally used for inbin drying or aera

Pagina 31

7Fan/Heater ApplicationFAN APPLICATION GUIDENOYESMAYBEYESNOMAYBE1750RPM Centrifugal Fans1750RPM Centrifugal fans are normally high performance, medium

Pagina 32 - PLENUM TEMPERATURES

8Fan/Heater ApplicationFAN & ROOF VENT SELECTIONSTEP 1. Determine the average grain depthfor a desired bin size:LEVEL FILL -AVE GRAIN DEPTH (ft)

Pagina 33 - June 1998

9Fan/Heater ApplicationAERATION SYSTEM REQUIREMENTSFull perforated floors are recom-mended in most DRYING situations. Floorgaugesand support spacing

Commenti su questo manuale

Nessun commento